We- NIson Intrusment (shanghai)Limited produce chemistry analyzer MOL-300 ,the techinical parameter as following : Analysis speed: 300TEST/H at most
Simultaneous on-line testing items: 60 for single-reagent items as maximum?dual-reagent items is reduced, sample feeding interval to be 12s Philosophy of measurement: Colorimetry (LAW OF BEER-LAMBERT ) & turbidimetry Discrete in structure ?unattached Cuvette?To avoid bringing intercross pollution Testing Method: End-point, Two-point, Fixed time, Kinetic Stochastic choice?Stochastically choose the sequence of testing sample and the testing item, in while
the emergency treatment owns the priority to be tested.
Sample tray?
Sample tray capacity: 60 (Samples or sample tray may be replaced to allow more samples to be measured) all available for calibrator, quality control and emergency treatment. Sample cup?compatible with various blood sampling tubes Sample volume?2?35?l(incremental by 0.1?l)?syringe capacity to be 50ul
Sample probe: Liquid level sensing, nonstick coating Pre-dilution mode: automatic dilution function to allow non-conforming sample to be automatically diluted for retesting.
Reagent tray:
Reagent tray: 60position/tray?can program for 6 reagent trays?, on-line refrigeration available, dynamic display of remaining reagent
Reagent volume: 180-450l for single-reagent items and 30-350l for reagent II of dual-reagent items. In the case of Kinetic or two-point velocity, 150-450l is for reagent I volume and 180-500l(incremental by 1?l)for total reagent volume, syringe capacity to be 500ul
Reagent probe: Liquid level sensing, nonstick coating
Reaction system?
Reaction tray: 10X9, 8 clusters on line simultaneously
to be 5?
below the set constant t

Do you want view original page?


1 - 5 of 66 results Select all on this page to
  • Timely Detection: When patient feels unwell or heart uncomfortable, the EASY ECG MONITOR can timely detect the abnormality of... More
  • Easy ECG Monitor (Model No.: Prince 180) is a new product that allows a person to carry and monitor heart anywhere any time.... More
  • HFsafe-900 Manual CLASS II Type A2
    Features:
    Highly efficient ULPA main filter, filtration efficiency... More
  • Easy ECG Monitor (Model No.: Prince 180) is a new product that allows a person to carry and monitor heart anywhere any time.... More
  • We- NIson Intrusment (shanghai)Limited produce chemistry analyzer MOL-300 ,the techinical parameter as following : Analysis... More